    an ecg monitor is a medical instrument used to and measure physiological parameters such as ecg, respiration, blood pressure, body temperature, and pulse of patients. it has functions such as information collection, storage, and intelligent analysis. operation of the monitor.

    1. prepare supplies, push the monitor to the patient's bed, check the wristband, bed number, name, hospital number.

    2. plug in the power supply, indicator light, and turn on the monitor.

    3. position the patient according to the situation, expose the chest, position the patient correctly, clean the patient's skin (prevent the electrode pads from cleaning with 5% alcohol if necessary), and paste the electrode pads.

    4. connecting the ecg lines: left upper (la) first intercostal line at the left sternum border; right lower (rl) right anterior midline xiphoid process level; left lower (ll) left axillary anterior xiphoid process level;

    5. non-invasive blood pressure monitoring: select an appropriate site and fasten the sphygmomanometer cuff; the marked arrow points to the brachial artery.

    6. through the modules of various monitors, ecg, nbp, and various monitoring technical parameters can be set: press a button to rotate at the bottom right, when the left and right start to rotate, it is the selection key, and press the confirmation key. ecg-select lead, amplitude and heart rate upper and lower alarm limits; nbp-select to control the working interval of blood pressure data monitoring and the upper and lower alarm limits.

    7. after measuring the blood pressure, press the "blood pressure start button", the corresponding p and blood pressure values ​​will appear on the display screen and be recorded on the nursing record sheet.

    8. stop monitoring: remove all output cables from under the patient and lay out the bed sheet unit.

    9. turn off the power switch and unplug the power supply.

    figure 10. clean the instrument and output cable with 75% alcohol, and replenish the electrode plate in time for spare.

    分享到:
    评论

    相关推荐

      finally, some games screenshots and data tables to introduce the basic operation of the game development and game design process. and in accordance with the method of software engineering, from ...

      p2p network is factually an overlay network for distributed object store, search and sharing. this paper will present a survey about it’s recent. first, we will introduce a simple ...evolution process.

      but the time when loss first occurs will be different from one experiment to the next due to the randomness in the emission process. 22. five generic tasks are error control, flow control, ...

      it is also shown that by using the proposed technique, the process of synchronization and grid connection do not introduce any changes into the system, which may cause protection devices to trip or ...

      level induction of influencing factors and selection of assessment indicators from the four aspects of team input, process, output and reinput, taking into account team construction, operation, ...

      perturbing the gyroscope signals, identifying white noise as the process which contributes most to the overall drift of the system. sensor fusion and domain specific constraints can be used to reduce ...

      when you include a header file you introduce a dependency that will cause your code to be recompiled whenever the header file changes. if your header file includes other header files, any change to ...

      the software that this text will introduce is a multi-function learn the single phrase software, mainly introduced this software manufacture environment, the manufacture process, to operation and its ...

      curvefinder operation), the comments in the graph info dialog were not correct. fixed. the cut last row/undo pair now functions properly. the the graph of a polynomial fit would be reset if ...

      to operation and its operation methods of the database.the customer can search the single phrase according to own demand, increasing the single phrase, ...

      aspects that have significant importance on the overall 3g network planning process: simplified as well as very detailed models of the umts radio network and its behaviour, modelling of geographical ...

      in addition to the default bochs method using the ctrl key and the middle mouse button there are now the choices: - ctrl f10 (like dosbox) - ctrl alt (like qemu) - f12 (replaces win32 'legacyf12'...